玻璃球色譜柱應(yīng)用安捷倫7890測(cè)定藥典二氧化碳
  • 玻璃球色譜柱應(yīng)用安捷倫7890測(cè)定藥典二氧化碳

  • 發(fā)布時(shí)間:2024-12-22 10:17:1
  • 產(chǎn)品簡(jiǎn)介:

    名稱:色譜柱
    固定相:玻璃球
    粒度:80mesh
    規(guī)格:0.8m*4mm
    型號(hào):HH-BLQ
咨詢熱線:0632-5667636

名稱:色譜柱
固定相:玻璃球
粒度:80mesh
規(guī)格:0.8m*4mm
型號(hào):HH-BLQ
應(yīng)用:2015/2020年版藥典二氧化碳中碳?xì)浠衔锏姆治?/span>

?

浩瀚色譜研制的玻璃球色譜柱,柱效高,分離好,和島津,賽默飛,瓦里安,布魯克,pe,磐諾,福立,北分瑞利等儀器,能實(shí)現(xiàn)互聯(lián)互通,結(jié)果滿意。

?

參考方法:

?

碳?xì)浠衔?取本品作為供試品氣體,取甲烷含量為0.0020%的氣體(以氮?dú)鉃橄♂寗┳鳛閷?duì)照氣體,照氣相色譜法(通則0521)試驗(yàn),用玻璃球?yàn)樘盍系纳V柱(4mm×0.8m,80目);柱溫為110℃;進(jìn)樣口溫度為110℃;檢測(cè)器為火焰離子化檢測(cè)器,溫度為120℃。量取供試品氣體與對(duì)照氣體,注入色譜儀,在凈化溫度為360℃時(shí)測(cè)得的峰面積為相應(yīng)空白值;量取供試品氣體與對(duì)照氣體,注入色譜儀,測(cè)定峰面積,減去相應(yīng)空白值后的峰面積為校正峰面積。按外標(biāo)法以校正峰面積計(jì)算,含碳?xì)浠衔铮ㄒ约淄橛?jì))不得過0.0020%。
?

5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱

?

Name: Chromatographic Column
Fixed phase: glass ball
Granularity: 80mesh
Specification: 0.8m * 4mm
Model: HH-BLQ
Application: Analysis of Hydrocarbons in Carbon Dioxide in the 2015/2020 Pharmacopoeia
The glass sphere chromatography column developed by Haohan Chromatography has high column efficiency and good separation. It can be interconnected with instruments such as Shimadzu, Thermo Fisher Scientific, Varian, Brooke, PE, Panno, Fuli, and Beifen Raleigh, and the results are satisfactory.
Reference method:
Hydrocarbons: This product is used as the test gas, and a gas with a methane content of 0.0020% (diluted with nitrogen) is used as the control gas. The gas chromatography method (General Rule 0521) is used for testing, and a chromatography column (4mm × 0.8m, 80 mesh) filled with glass spheres is used; The column temperature is 110 ℃; The inlet temperature is 110 ℃; The detector is a flame ionization detector with a temperature of 120 ℃. Measure the test gas and control gas, inject them into the chromatograph, and measure the peak area at a purification temperature of 360 ℃ as the corresponding blank value; Measure the test gas and control gas, inject them into the chromatograph, measure the peak area, and subtract the corresponding blank value to obtain the corrected peak area. According to the external standard method, the corrected peak area should not exceed 0.0020% for hydrocarbons (calculated as methane).