便攜式甲烷轉(zhuǎn)化爐安裝在PE580色譜儀上測大氣中CO
  • 便攜式甲烷轉(zhuǎn)化爐安裝在PE580色譜儀上測大氣中CO

  • 發(fā)布時(shí)間:2024-12-8 10:45:17
  • 產(chǎn)品簡介:
    名稱:甲烷轉(zhuǎn)化爐

    填料:鎳觸媒”
    規(guī)格:HH-790CH4-GC

    應(yīng)用:微量一氧化碳,二氧化碳轉(zhuǎn)化成甲烷
咨詢熱線:0632-5667636

一氧化碳為一毒性氣體,極微量濃度即具毒性.當(dāng)空氣中含有一氧化碳達(dá)0.02—0.05%(容積)時(shí),若長時(shí)期接觸,就可引致頭痛,頭暈,心跳加快等癥狀.達(dá)0.1—0.2%時(shí),癥狀出現(xiàn)加快且加劇,甚至發(fā)生呼吸困難,惡心和昏迷.達(dá)0.3—0.4%時(shí),可危及生命,

 

工作場所每升空氣中一氧化碳的最大容許量為0.02—0.03毫克.

 

浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司,,研制便攜式甲烷轉(zhuǎn)化爐在PE580氣相色譜儀上次的大氣中微量的一氧化碳,氧氣不干擾一氧化碳的響應(yīng),柱效高,分離好,互聯(lián)互通,安裝簡單,效率高。

 

名稱:甲烷轉(zhuǎn)化爐

填料:鎳觸媒”
規(guī)格:HH-790CH4-GC

應(yīng)用:微量一氧化碳,二氧化碳轉(zhuǎn)化成甲烷

特點(diǎn);

  1. 無需改造儀器,直接對接,省時(shí),省力,實(shí)現(xiàn)不同規(guī)格型號(hào)的儀器互聯(lián)互通

  2. 含進(jìn)樣裝置,色譜柱系統(tǒng),溫控系統(tǒng),可選擇中心切割技術(shù),保護(hù)催化劑,延長使用壽命。

  3. 可連接安捷倫6890/7890/7820/8860/8890;島津GC2010/2014/2030;賽默飛1310系列;瓦里安3400系列;PE,布魯克;磐諾A90系列;北分瑞利3400系列;福立9790系列;川儀,天瑞,天美,華愛,科曉,捷島,

4.體積小,方便攜帶,安裝簡單:一進(jìn),一出2個(gè)接口

 

5A分子篩填充柱

5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱

 

Carbon monoxide is a toxic gas that is toxic at very low concentrations When the air contains carbon monoxide up to 0.02-0.05% by volume, prolonged exposure can cause symptoms such as headaches, dizziness, and increased heart rate When it reaches 0.1-0.2%, symptoms accelerate and worsen, and even lead to difficulty breathing, nausea, and coma When it reaches 0.3-0.4%, it can be life-threatening,
The maximum allowable amount of carbon monoxide per liter of air in the workplace is 0.02-0.03 milligrams
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has developed a portable methane conversion furnace for detecting trace amounts of carbon monoxide in the atmosphere using the PE580 gas chromatograph. Oxygen does not interfere with the response of carbon monoxide, resulting in high column efficiency, good separation, interconnectivity, simple installation, and high efficiency.
Name: Methane Converter
Filler: Nickel Catalyst
Specification: HH-790CH4-GC
Application: Trace carbon monoxide, carbon dioxide converted to methane
characteristic;
No need to modify the instrument, direct docking, saving time and effort, realizing interconnection and intercommunication of instruments of different specifications and models
Equipped with an injection device, chromatographic column system, temperature control system, and optional central cutting technology to protect the catalyst and extend its service life.
Can connect to Agilent 6890/7890/7820/8860/8890; Shimadzu GC2010/2014/2030; Thermo Fisher 1310 series; Varian 3400 series; PE, Brooke; Panno A90 series; Northern Raleigh 3400 series; Fuli 9790 series; Chuan Yi, Tian Rui, Tian Mei, Hua Ai, Ke Xiao, Jie Dao,
4. Small size, easy to carry, simple installation: one in, one out 2 interfaces